In some cases, where a major component needs replacing, you might want to consider buying a new boiler and we have recommended you get a quote from WarmZilla to do so. Just like other boiler makes, Vaillant boilers will display a fault code – a number beginning with F – on their display so you can more easily identify what may be going wrong with your system. Different issues will have a different error code so if you see an F number displayed, refer to your boiler’s manual for the full list of fault codes for that model. How Long Should a Vaillant Boiler Last? Low water pressure will affect all boilers at some point in their working life, and your Vaillant boiler should be monitoring the water pressure in case it drops below the normal level, which is typically 1 – 1.5 bar.

Vaillant PCB 0020132764 is effectively the brain of your boiler, It is programmed to ensure everything is running as it should. Some Gas engineers refer to this as Vaillant PCB 0r as Vaillant Circuit Board 0020132764 or as ecoTEC Circuit Board 0020132764. The fix –as gas is involved in this common Vaillant Boiler fault, you must always call a Gas Safe registered engineer and never attempt to fix the problem yourself. Your engineer may be able to fix or replace the gas valve or other affected components. But it may be that you need to upgrade your system and get a new boiler.Boiler ignition failure will leave you without heating or hot water if it is not resolved so this is not an issue to ignore. Your ignition is essential, and it keeps the flame burning, which in turn heats up water as it passes through the pipe. A faulty or failed ignition is a relatively common issue with Vaillant boilers and will be displayed as an F28 fault code which you need to look into. If the boiler doesn’t reset, don’t keep pressing the reset button as this can cause further damage, but call out a Gas Safe registered engineer.

Use trace heating if required and installed according to the trace heating manufacturers recommended instructions. The PCB is your boiler’s motherboard – the essential component that links everything else together and keeps the boiler working. While Vaillant have a reputation for quality and affordability, like all boilers they can also be prone to faults over time. And there are a few glitches that are common issues across the Vaillant range. Buy your Vaillant 0020132764 - Ecotec Pro 28 Vuw 286/3-3 R1 Printed Circuit Board today, with a fast UK delivery..If you are getting an F75 error code, it is almost certain you have an older model of Vaillant boiler. These older models were fitted with a Wilo pump, as we mentioned above, and these are known for being unreliable and easy to break. Not what you're looking for? Try our unique Spares Finder tool or you can view all Vaillant Boiler Spares products. The first instinct most people have when there is a problem with their boiler is to call out an engineer. Sometimes this is needed, but there are times when you can fix the issue quite simply yourself. Buy your Vaillant 0010028086 - Ecotec Pro 28 Vuw 286/5-3 Printed Circuit Board today, with a fast UK delivery.. Central heating pump issues most commonly result in error code F75 and is something we see most on theVaillant Eco Tec Plus range and on the Eco Tec Pro 28 in particular.

The fix –as the boiler is an internal component, it is advisable to call out a Gas Safe engineer to assess and fix any problems with your pump or pressure sensor. If you have an older model, the pump can be upgraded, and the system flushed to get rid of all that debris build-up. The engineer can also replace a faulty pressure sensor if that is found to be the real cause of the error code display. When a Valliant boiler does go wrong, the display panel will show a fault code. This code is designed to tell the engineer what the issue is to speed up the fix. But it is something you can use to help you solve the problem and save some money on engineer fees too. #1 – Low or no pressure

F.70 Solution / Repair

This fault code is known to show up with fault code F27. The difference between F27 and F28 is that F27 is failure immediately after ignition, whereas F28 is complete failure to ignite. Part Numbers

This issue is a more complex one since the number of possible causes is much higher and it could be a problem with the gas supply element of your boiler. As a result, this is one that you will need to get a qualified gas engineer out to take a look at. Our focus in this guide is Valliant boilers. They are generally pretty reliable but there are some faults that we see occurring repeatedly. The possible causes– there are several main reasons why your Vaillant Combi boiler’s ignition is refusing to light. The first is an issue with your gas supply, meaning there is no fuel to feed the ignition process. Alternatively, it could be a frozen condensate pipe, which takes vapour and waste water out of the boiler and into an outside drain and can cause a shutdown of your boiler, including the pilot light. The third reason could be faulty electrode or ignition leads which can wear out and means your boiler’s ignition cannot create the essential spark to get things started. When buying a Vaillant boiler, their standard warranty covers between two and five years, with the option to extend up to 10 years on some products. A boiler that is 10 years or more is considered an old boiler, but if you look after your Vaillant and ensure it is serviced annually, there’s no reason it shouldn’t last longer. How do I Reset my Vaillant Boiler? The VAILLANT 0020132764 PRINTED CIRCUIT BOARD is a genuine, brand new Vaillant Boiler Spares product, covered by a Vaillant Boiler Spares manufacturer's guarantee.vaillant ecotec pro 28 printed circuit board with connectors disconnectedWith this boiler, the circuit board would put power onto the fan which would spin for a second and then the screen would go blank for a period.